Details
- Pure Sine Wave Output
- DSP Digital Control
- Boost and Buck AVR for Voltage Stabilization
- Auto Sensing Frequency
- Adjustable Charging Current and Battery Shutdown Point
- Settable ECO Mode and No-load Shutdown
- Humanized Alarm System
- Power-on Self Test
- Cold Start
- Auto Restart When Mains Power is Restored
- Intelligent Battery Management
- Short Circuit and Overload Protection
- Automatic Charging in Off Mode
- USB & RJ45, AS400 / SNMP (optional)
| SNC-2000R UPS SMART NET CLAIRE Series | |
| MODEL | SNC-2000R |
| Capacity | 2000VA/1600W |
| DC INPUT | |
| Rated voltage | 36V(S) 48V(H) |
| DC INPUT range (default) | 30-45V(S) 40-60V(H) |
| AC INPUT | |
| AC input range(bypass mode) | 0~121/132/138/144 Vac for 100/110/115/120 Vac ± 10 Vac |
| 0~242/264/276/288 Vac for 200/220/230/240 Vac ± 10 Vac | |
| AC input range(mains mode) | 100V:70~130Vac 110V:80~140Vac 115V:85~145Vac 120V:90~150Vac |
| 200V:145~260Vac 220V:165~280Vac 230V:175~290Vac 240V:185~300Vac | |
| Frequency input range | 50/60Hz(auto-sensing),50/60Hz ± 5%~15% |
| Generator connection | Available (generator input power is settable) |
| OUTPUT | |
| Inverter output range | 100/110/115/120/200/220/230/240 Vac ± 5% (settable) |
| AC output range(bypass mode) | 0~121/132/138/144 Vac for 100/110/115/120 Vac ± 10 Vac |
| 0~242/264/276/288 Vac for 200/220/230/240 Vac ± 10 Vac | |
| AC output range(mains mode) | 100V:90~110Vac 110V:99~121Vac 115V:103~126Vac 120V:108~132Vac |
| 200V:166~226Vac 220V:188~245Vac 230V:199~254Vac 240V:210~264Vac | |
| Output frequency | 50/60Hz ± 0.3Hz(settable) |
| Waveform | Pure sine wave |
| Inverter efficiency | Max. 85% |
| Energy saving mode | Settable(<3% load),enter in 80s |
| No-load shutdown | Settable(<3% load),shut down in 80s |
| Transfer time | ≤10ms |
| THDV(resistive load) | ≤5% |
| Protections | Overload,short circuit(inverter),battery low voltage,battery overcharge,overtemperature |
| Overload(mains mode) | 110% for 120s,125% for 60s,150% for 10s(transfer to bypass mode) |
| Overload(inverter mode) | 110% for 60s,125% for 10s,150% for 5s(shut down directly) |
| Mute | Automatic mute in 60s or by manual |
| BATTERIES | |
| Inbuilt battery(standard model) | 12V/9 Ah×3 |
| Charging Current | Standard model(S):1 A(default) |
| Long time model(H):10A(default):<10A,set step 1A:?10A,set step 5A | |
| Max. 20 A(H) | |
| Equalizing charge voltage | Single battery 14.1 Vdc(default),13.6~15Vdc adjustable |
| Floating charge voltage | Single battery 13.5 Vdc(default),13.2~14.6Vdc adjustable |
| Low voltage alarm point | Single battery 10.8 Vdc(default),9.6~13Vdc adjustable |
| Low voltage shutdown point | Single battery 10.2 Vdc(default),9.6~11.5Vdc adjustable |
| OTHERS | |
| Communications | USB & RJ45(standard),dry contacts/SNMP(optional) |
| Operating temperature | 5°C-40°C |
| Operating humidity | Relative humidity≤93% |
| Noise level | ≤50dB(1m) |
| Rack-mount | |
| Dimension(W×D×H)(mm) | 440×410×132(S) |
| Packaged dimensions(W×D×H)(mm) | 611×505×235(S) |
| Net weight | 21.3(S) |
| Gross weight(kg) | 24.5(S) |
View more about SNC-2000R UPS SMART NET CLAIRE Series on main site